{"id":303,"date":"2016-10-04T12:28:33","date_gmt":"2016-10-04T04:28:33","guid":{"rendered":"http:\/\/mjiit.utm.my\/microscopy-lab\/?page_id=303"},"modified":"2021-01-31T18:45:27","modified_gmt":"2021-01-31T10:45:27","slug":"field-emission-transmission-electron-microscope-fetem","status":"publish","type":"page","link":"https:\/\/mjiit.utm.my\/microscopy-lab\/field-emission-transmission-electron-microscope-fetem\/","title":{"rendered":"Field-Emission Transmission Electron Microscope (FETEM)"},"content":{"rendered":"<h1><span style=\"font-family: arial, helvetica, sans-serif\"><a href=\"https:\/\/mjiit.utm.my\/microscopy-lab\/wp-content\/uploads\/sites\/72\/2016\/09\/tem__.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-255\" src=\"https:\/\/mjiit.utm.my\/microscopy-lab\/wp-content\/uploads\/sites\/72\/2016\/09\/tem__.jpg\" alt=\"tem__\" width=\"690\" height=\"498\" srcset=\"https:\/\/mjiit.utm.my\/microscopy-lab\/wp-content\/uploads\/sites\/72\/2016\/09\/tem__.jpg 997w, https:\/\/mjiit.utm.my\/microscopy-lab\/wp-content\/uploads\/sites\/72\/2016\/09\/tem__-300x216.jpg 300w, https:\/\/mjiit.utm.my\/microscopy-lab\/wp-content\/uploads\/sites\/72\/2016\/09\/tem__-768x554.jpg 768w\" sizes=\"(max-width: 690px) 100vw, 690px\" \/><\/a><\/span><\/h1>\n<p><span style=\"font-family: arial, helvetica, sans-serif\"><a href=\"https:\/\/mjiit.utm.my\/microscopy-lab\/wp-content\/uploads\/sites\/72\/2016\/10\/TEM-4_.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-608\" src=\"https:\/\/mjiit.utm.my\/microscopy-lab\/wp-content\/uploads\/sites\/72\/2016\/10\/TEM-4_-300x200.jpg\" alt=\"tem-4_\" width=\"280\" height=\"187\" srcset=\"https:\/\/mjiit.utm.my\/microscopy-lab\/wp-content\/uploads\/sites\/72\/2016\/10\/TEM-4_-300x200.jpg 300w, https:\/\/mjiit.utm.my\/microscopy-lab\/wp-content\/uploads\/sites\/72\/2016\/10\/TEM-4_-768x512.jpg 768w, https:\/\/mjiit.utm.my\/microscopy-lab\/wp-content\/uploads\/sites\/72\/2016\/10\/TEM-4_-1024x682.jpg 1024w, https:\/\/mjiit.utm.my\/microscopy-lab\/wp-content\/uploads\/sites\/72\/2016\/10\/TEM-4_.jpg 1280w\" sizes=\"(max-width: 280px) 100vw, 280px\" \/><\/a>\u00a0 \u00a0\u00a0<a href=\"https:\/\/mjiit.utm.my\/microscopy-lab\/wp-content\/uploads\/sites\/72\/2016\/10\/TEM-2_.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-600\" src=\"https:\/\/mjiit.utm.my\/microscopy-lab\/wp-content\/uploads\/sites\/72\/2016\/10\/TEM-2_-300x200.jpg\" alt=\"tem-2_\" width=\"280\" height=\"187\" srcset=\"https:\/\/mjiit.utm.my\/microscopy-lab\/wp-content\/uploads\/sites\/72\/2016\/10\/TEM-2_-300x200.jpg 300w, https:\/\/mjiit.utm.my\/microscopy-lab\/wp-content\/uploads\/sites\/72\/2016\/10\/TEM-2_-768x512.jpg 768w, https:\/\/mjiit.utm.my\/microscopy-lab\/wp-content\/uploads\/sites\/72\/2016\/10\/TEM-2_-1024x682.jpg 1024w, https:\/\/mjiit.utm.my\/microscopy-lab\/wp-content\/uploads\/sites\/72\/2016\/10\/TEM-2_.jpg 1280w\" sizes=\"(max-width: 280px) 100vw, 280px\" \/><\/a><\/span><\/p>\n<h2 style=\"text-align: left\"><span style=\"font-family: arial, helvetica, sans-serif\"><strong>FIELD EMISSION TRANSMISSION ELECTRON MICROSCOPE (FETEM)<\/strong><\/span><\/h2>\n<div style=\"text-align: left\"><span style=\"font-family: arial, helvetica, sans-serif\"><span style=\"font-size: 16px\">Brand<\/span> :<span style=\"font-size: 16px\"> JEOL<\/span><\/span><\/div>\n<div style=\"text-align: left\"><span style=\"font-family: arial, helvetica, sans-serif\"><span style=\"font-size: 16px\">Model<\/span> :<span style=\"font-size: 16px\"> JEM-2100F<\/span><\/span><\/div>\n<div>\n<table style=\"height: 251px;width: 573px\">\n<tbody>\n<tr style=\"height: 24px\">\n<td style=\"width: 203px;border-color: #030303;background-color: #62e3e3;height: 24px\"><span style=\"font-size: 14px;font-family: arial, helvetica, sans-serif\"><strong>Details<\/strong><\/span><\/td>\n<td style=\"width: 364px;border-color: #030303;background-color: #62e3e3;height: 24px\"><span style=\"font-size: 14px;font-family: arial, helvetica, sans-serif\">\u00a0<\/span><\/td>\n<\/tr>\n<tr style=\"height: 315.688px\">\n<td style=\"width: 203px;height: 315.688px\"><span style=\"font-size: 16px;font-family: arial, helvetica, sans-serif\">Details of Instrument<\/span><\/td>\n<td style=\"width: 364px;height: 315.688px\">\n<p style=\"text-align: justify\"><span style=\"font-size: 16px;font-family: arial, helvetica, sans-serif\">The JEM-2100F is an advanced Field Emission Electron Microscope featuring\u00a0ultrahigh\u00a0resolution and rapid data acquisition. The JEM 2100F is a next generation TEM that simplifies atomic level structural analyses in biology, medicine, and materials sciences as well as the semiconductor and pharmaceutical industries. The JEM-2100F has been developed to achieve the highest image quality and the highest analytical performance in the 200kV class analytical TEM with a probe size under 0.5nm. The new side-entry goniometer stage provides ease of use tilt, rotation, heating and cooling, programmable multi-point settings&#8211;all without mechanical drift. The JEM-2100F can be equipped with STEM, MDS, EDS, and CCD-cameras.<\/span><\/p>\n<\/td>\n<\/tr>\n<tr style=\"height: 315.688px\">\n<td style=\"width: 203px;height: 315.688px\"><span style=\"font-family: arial, helvetica, sans-serif;font-size: 16px\">Sample Image<\/span><\/td>\n<td style=\"width: 364px;height: 315.688px\">\n<p style=\"text-align: justify\"><span style=\"font-size: 16px;font-family: arial, helvetica, sans-serif\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-1395\" src=\"https:\/\/mjiit.utm.my\/microscopy-lab\/wp-content\/uploads\/sites\/72\/2016\/10\/1-Si-FFT-pattern-300x300.jpg\" alt=\"\" width=\"300\" height=\"300\" srcset=\"https:\/\/mjiit.utm.my\/microscopy-lab\/wp-content\/uploads\/sites\/72\/2016\/10\/1-Si-FFT-pattern-300x300.jpg 300w, https:\/\/mjiit.utm.my\/microscopy-lab\/wp-content\/uploads\/sites\/72\/2016\/10\/1-Si-FFT-pattern-150x150.jpg 150w, https:\/\/mjiit.utm.my\/microscopy-lab\/wp-content\/uploads\/sites\/72\/2016\/10\/1-Si-FFT-pattern-768x768.jpg 768w, https:\/\/mjiit.utm.my\/microscopy-lab\/wp-content\/uploads\/sites\/72\/2016\/10\/1-Si-FFT-pattern-1024x1024.jpg 1024w, https:\/\/mjiit.utm.my\/microscopy-lab\/wp-content\/uploads\/sites\/72\/2016\/10\/1-Si-FFT-pattern.jpg 2048w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/span><\/p>\n<\/td>\n<\/tr>\n<tr style=\"height: 46px\">\n<td style=\"width: 203px;height: 46px\"><span style=\"font-size: 16px;font-family: arial, helvetica, sans-serif\">Service Charge<\/span><\/td>\n<td style=\"width: 364px;height: 46px\">FETEM Fee per sample :-<\/p>\n<ul style=\"list-style-type: square\">\n<li style=\"text-align: left\">Student\/Staff MJIIT <strong>(RM320)<\/strong><\/li>\n<li style=\"text-align: left\">Student\/Staff UTM <strong>(RM400)<\/strong><\/li>\n<li style=\"text-align: left\">Student\/Staff Other University <strong>(RM460)<\/strong><\/li>\n<li style=\"text-align: left\">Industry <strong>(RM500)<\/strong><\/li>\n<\/ul>\n<p>EDS Fee per sample :-<\/p>\n<ul style=\"list-style-type: square\">\n<li>Student\/Staff MJIIT <strong>(RM120)<\/strong><\/li>\n<li>Student\/Staff UTM <strong>(RM150)<\/strong><\/li>\n<li>Student\/Staff Other University <strong>(RM180)<\/strong><\/li>\n<li>Industry <strong>(RM300)<\/strong><\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr style=\"height: 36px\">\n<td style=\"width: 203px;height: 36px\"><span style=\"font-size: 16px;font-family: arial, helvetica, sans-serif\">Operation\u00a0Hours<\/span><\/td>\n<td style=\"width: 364px;height: 36px\"><span style=\"font-size: 16px;font-family: arial, helvetica, sans-serif\">9.00 a.m. \u2013 4.30 p.m.<\/span><\/td>\n<\/tr>\n<tr style=\"height: 48px\">\n<td style=\"width: 203px;height: 48px\"><span style=\"font-size: 16px;font-family: arial, helvetica, sans-serif\">Status<\/span><\/td>\n<td style=\"width: 364px;height: 48px\"><span style=\"font-size: 16px;font-family: arial, helvetica, sans-serif\">Available for Booking<\/span><\/td>\n<\/tr>\n<tr style=\"height: 75px\">\n<td style=\"width: 203px;height: 75px\"><span style=\"font-size: 16px;font-family: arial, helvetica, sans-serif\">P.I.C<\/span><\/td>\n<td style=\"width: 364px;height: 75px\">\n<div style=\"text-align: left\">\n<div style=\"text-align: left\"><span style=\"font-family: arial, helvetica, sans-serif\"><span style=\"font-size: 16px\">\u00a0<\/span><span style=\"font-size: 16px\">-For Booking<\/span><\/span><\/div>\n<div style=\"text-align: left\"><span style=\"font-size: 16px;font-family: arial, helvetica, sans-serif\">microscopylaboratorymjiit@gmail.com<\/span><\/div>\n<div style=\"text-align: left\"><span style=\"font-size: 16px;font-family: arial, helvetica, sans-serif\">03-2203 1527<\/span><\/div>\n<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u00a0 \u00a0\u00a0 FIELD EMISSION TRANSMISSION ELECTRON MICROSCOPE (FETEM) Brand : JEOL Model : JEM-2100F Details \u00a0 Details of Instrument The JEM-2100F is an advanced Field Emission Electron Microscope featuring\u00a0ultrahigh\u00a0resolution and rapid data acquisition. The JEM 2100F is a next generation TEM that simplifies atomic level structural analyses in biology, medicine, and materials sciences as well [&hellip;]<\/p>\n","protected":false},"author":122,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"open","template":"","meta":{"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":"","footnotes":""},"class_list":["post-303","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/mjiit.utm.my\/microscopy-lab\/wp-json\/wp\/v2\/pages\/303","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/mjiit.utm.my\/microscopy-lab\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/mjiit.utm.my\/microscopy-lab\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/mjiit.utm.my\/microscopy-lab\/wp-json\/wp\/v2\/users\/122"}],"replies":[{"embeddable":true,"href":"https:\/\/mjiit.utm.my\/microscopy-lab\/wp-json\/wp\/v2\/comments?post=303"}],"version-history":[{"count":39,"href":"https:\/\/mjiit.utm.my\/microscopy-lab\/wp-json\/wp\/v2\/pages\/303\/revisions"}],"predecessor-version":[{"id":3029,"href":"https:\/\/mjiit.utm.my\/microscopy-lab\/wp-json\/wp\/v2\/pages\/303\/revisions\/3029"}],"wp:attachment":[{"href":"https:\/\/mjiit.utm.my\/microscopy-lab\/wp-json\/wp\/v2\/media?parent=303"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}